One genome, 401 results. 54 at the default thresholds.
Genokeeper takes the raw reads of a 30x genome and calls them on your own machine. It grades every result twice: how likely the genotype is wrong, measured against a truth set wherever one reaches, and how strong the evidence behind the claim is. This page is its output for HG002, a public reference genome. As far as we found (November 2026), it is the first open-source personal-genome tool to show, on each genotype call, the chance it is wrong as measured on Genome in a Bottle samples in its own calibration runs.
| results that remain | any evidenceany | limited or morelimited+ | moderate or moremoderate+ | strongstrong |
|---|---|---|---|---|
| high onlyhigh | 267 | 169 | 33 | 5 |
| medium or bettermedium+ | 376 | 233 | 54default | 19 |
| any genotypeany | 401everything | 242 | 57 | 21 |
What a newer ClinVar changed
The reads are the same. Between its releases of 2026-05-03 and 2026-11-08, ClinVar brought 149 changes; 14 results entered or left the list of everything called, and 0 entered or left the list at the default thresholds.
All changes, with their sources
Ask it
Three steps put this genome in a folder you can ask questions about. The download sends nothing.
- Get the folder (macOS or Linux).uvx genokeeper demo
- Open it in your agent; in Claude Code:cd ~/genokeeper-demo && claude
- Ask.Is HG002 a carrier of anything their children could inherit?
Recorded on 2026-11-14 from genokeeper 0.2.1.
> Is HG002 a carrier of anything their children could inherit? **Short answer:** the store has no confirmed carrier finding for HG002. It does have three low-confidence screening or prediction results, none of them confirmed. All of this is from run `20261114T101533Z-bd04e4` (ClinVar 20261108). Under the default view, which is validity moderate or better and reliability medium or better, there are no carrier findings. An empty list is not a "not a carrier" result. I lowered the filters (`--min-validity limited --min-reliability low`) to look further. Three results appear. None is a confirmed carrier status, and none is actionable. [An excerpt. The answer goes on to the three one by one (a predicted NEB splice change with a reliable genotype, and an NEB copy-number loss and an MLC1 insertion that are very likely false), the genes it could not assess (SMN1, STRC, HBA2, most of NEB, FMR1 and AFF2 withheld), and what to raise with a geneticist.]
Asking is optional and goes through the agent and model you choose: what a question needs is sent to that model's provider, and with a local model nothing leaves the machine. The skill reads a local command's JSON (genokeeper query --json), so any agent can use it.
How often it is wrong
Genotypes carry a measured error rate: small variants, and the kinds of call in the table below. Polygenic scores, GWAS associations and VEP predictions carry none of their own; only the genotypes under them are measured. This run is HG002's PCR-free library, so the rows marked "same sample" are shown on the data they were measured on, and HG002 may be in DeepVariant's training data.
| Class | Truth set; measured on | Events in truth | Found | Share of calls false | What the tool does with it | For HG002 |
|---|---|---|---|---|---|---|
| Small-variant genotypes, chr1-22 | GIAB v4.2.1; HG003 | — | SNP F1 0.99614, INDEL F1 0.99612 | — | Grades each genotype by its cell's measured error rate. | related sample |
| Small-variant genotypes on chrX, chrY and v5.0q-only regions | GIAB v5.0q; HG002 PCR-free | — | — | — | Grades each genotype by its cell's measured error rate. | same sample |
| SMN1 and SMN2 copies, repeat lengths, the Y haplogroup | GIAB v5.0q; a healthy sample; HG002 PCR-free and PCR; HG003 and HG004 for repeats | — | — | — | Withholds a locus or gene a library got wrong; the rest carry the test that confirms them. | same sample |
| Deletions of 50 bp or more in ACMG SF and carrier genes | GIAB v5.0q structural variants; HG002 PCR-free and PCR | 7,457 | 1,281 (pcr), 1,414 (pcrfree) | 35% | None is trustworthy without confirmation: each is shown only with a confirm-by note (MLPA, a microarray, qPCR or long reads). | same sample |
| Copy number from read depth | GIAB v5.0q; spike-ins; HG002 PCR-free and PCR, HG003, HG004 | 120 | 70 (pcr), 50 (pcrfree) | 89% | None is trustworthy without confirmation: each is graded by its class's chance of being false, never as likely. | same sample |
| Insertions and mobile elements | GIAB v5.0q structural variants; HG002 PCR-free and PCR | 14,364 | 1,587 (pcr), 1,739 (pcrfree) | 53% | None is trustworthy without confirmation: each is graded by its class's chance of being false, never as likely. | same sample |
| Paralog loci (GBA1, Lp(a) and others) | a published HG002 copy-number list; HG002 PCR-free and PCR, HG003, HG004 | — | — | — | Withholds a locus no library measured; the rest carry a confirm-by note. | same sample |
| Run-time checks: sex dosage, allele fraction | known sexes; GIAB v5.0q heterozygotes; HG002 PCR-free and PCR, HG003, HG004 | — | — | — | Sets the bounds of the run-time checks, which flag a run outside them. | same sample |
| HLA, chrM variants, HHV-6, runs of homozygosity, blood groups, ancestry | GIAB truths; the trio's inheritance; HG002 PCR-free, HG003, HG004 | — | — | — | Withholds what no library could measure; the rest carry the test that confirms them. | same sample |
Small variants are called by DeepVariant 1.10.0 with Google's Complete Genomics T7 checkpoint. Measured here on HG003, chr1-22: SNP F1 0.99614, INDEL F1 0.99612. Google's published figures for that checkpoint: SNP F1 0.997509 and INDEL F1 0.998207 on HG001 chr20 (DeepVariant r1.10, Complete Genomics T7 case study).
A clean result is not an exclusion: a variant the callers missed leaves no result. This run holds 131 withheld values: each is not graded and keeps its reason (a calibration table could not measure the item, or a deletion of a megabase or more leaves the read depth as it is). Every table as the tool printed it.
What it cannot do
- It reads only paired FASTQ from a DNBSEQ-T7 run of about 30x. Illumina reads are refused.
- Your own run needs an Apple silicon Mac with 48 GB, about 1 TB of free disk and several days.
- It is not a medical device. A finding is a reason to repeat the test in a clinical lab. No finding is not an all-clear. Results belong with a genetic counsellor or a clinician.
Built on
Genokeeper runs 75 published tools, truth sets and knowledge sources. All of them, with their papers and this run's versions.